home page

news

GLOSSARY OF TERMS

SEND YOUR ENQUIRY

STABILISERS - GUIDE

WHERE WE ARE

CONTACT US

PRODUCTS

SINGLE PHASE TRANSFORMERS

CONTROL

TE (50-3000VA)

MC (4000-20000VA)

ISOLATION AND SAFETY

sft (50-2000VA)

ALX IP55 12V (200-500VA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical use)

THREE PHASE TRANSFORMERS

POWER

TTP (1-100kVA)

ISOLATION

TTI (1-40kVA)

AUTOTRANSFORMERS

ATSE (1 PH. 0,1-5kVA)

ATTP (3 PH. 1-300kVA)

ATTP1 (3 PH. ENCL. 1-300kVA)

ATV (MOTOR START.  7-220kW)

---------

METAL ENCLOSURES

VOLTAGE STAbILISERS

SE 1 PH. ELECTRONIC TO 10KVA 

SEI LINE CONDITIONERS TO 2000VA

SV 1 PH. ELECTROMECH.TO 10KVA 

svD 1 PH. ELECTROM. TO 20KVA

ST 3 ph. electrom. to 30KVA

STI  3 ph. conditioners to 30KVA

RTG 3 ph. electrom. to 500KVA

lnM 1ph. electronic to 25kva

lnt 3ph. electronic  to 75KVA

more products here 

versione italiana

copyright 2002-2003 by:

web factory
last update 25/11/2003

credits

SINGLE PHASE SEPARATION TRANSFORMERS MC RANGE

POWER INPUT OUTPUT FREQUENCY STANDARDS
FROM 4000 TO 20000VA 220V 12/24V 50/60 Hz EN 61558-2-1
24/48V IEC 76
DA 110 A 550V 55/110V CEI 14-4
110/220V BS 171
Open type
Protection IP00
Isolation class E (Ta max 45°C)
Separate copper windings cl. F-H
Resin impregnated and tropicalised
Connections on DIN rail terminals to 10kVA (or 63A)
Connecitons on brass bolts from 15kVA (or  64A)
Encapsulated in metal enclosure on request




power part no. dimensions mm. DWG weight box
VA A B C D E F kg. code
4000 MC1...11 240 240 320 200 135 12 A 35.0 SA02
5000 MC1...12 240 250 320 200 145 12 A 37.0 SA02
7500 MC1...13 280 240 400 220 155 12 A 52.0 SA03
10000 MC1...14 280 250 400 220 165 12 A 61.0 SA03
15000 MC1...16 320 260 450 260 185 12 B 89.0 SA04
20000 MC1...17 320 280 450 260 205 12 B 99.0 SA04
ASK FOR CODES AND SPECIFICATION OF HIGHER RATINGS

add the following codes to complete the part number
according to the secondary voltage required

SEC

...

12-24V

1

24-48V

2

55-110V

3

110-220V

4

ASK FOR THE PART NUMBERS FOR A DIFFERENT PRIMARY VOLTAGE.
PRIMARY VOLTAGE IS AVAILABLE FROM 110V TO 550V

A

B

power losses inrush VA as a function of cos-phi short circ. regulation
VA W 0.9 0.8 0.7 0.6 0.5 0.4 voltage % %
4000 140 8200 8600 9200 9500 11400 13600 4.8 <5
5000 175 8500 11300 11900 12700 13600 14800 5.2 <5
7500 250 12750 13630 15000 17300 19470 21600 5.0 <5
10000 325 17000 18460 21000 23400 25200 28400 4.6 <5
15000 450 24400 26400 27000 31800 36200 41000 5.0 <5
20000 560 28000 30800 32100 36000 42300 50100 4.8 <5