home page

news

GLOSSARY OF TERMS

SEND YOUR ENQUIRY

STABILISERS - GUIDE

WHERE WE ARE

CONTACT US

PRODUCTS

SINGLE PHASE TRANSFORMERS

CONTROL

TE (50-3000VA)

MC (4000-20000VA)

ISOLATION AND SAFETY

sft (50-2000VA)

ALX IP55 12V (200-500VA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical use)

THREE PHASE TRANSFORMERS

POWER

TTP (1-100kVA)

ISOLATION

TTI (1-40kVA)

AUTOTRANSFORMERS

ATSE (1 PH. 0,1-5kVA)

ATTP (3 PH. 1-300kVA)

ATTP1 (3 PH. ENCL. 1-300kVA)

ATV (MOTOR START.  7-220kW)

---------

METAL ENCLOSURES

VOLTAGE STAbILISERS

SE 1 PH. ELECTRONIC TO 10KVA 

SEI LINE CONDITIONERS TO 2000VA

SV 1 PH. ELECTROMECH.TO 10KVA 

svD 1 PH. ELECTROM. TO 20KVA

ST 3 ph. electrom. to 30KVA

STI  3 ph. conditioners to 30KVA

RTG 3 ph. electrom. to 500KVA

lnM 1ph. electronic to 25kva

lnt 3ph. electronic  to 75KVA

more products here 

versione italiana

copyright 2002-2003 by:

web factory
last update 25/11/2003

credits

DOUBLE RANGE ELECTROMECHANICAL STABILISERS SVD range

POWER INPUT OUTPUT FREQUENCY SPEED ACCURACY
FROM 1,6KVA TO 20KVA FROM 190V TO 245V 220V 50/60 Hz 20 mSEC/V ± 1,5%
FORM 165V TO 270V
The continuous evolution of EMC rules and the needs of areas with large voltage variations brought to the new SVD electromechanical voltage stabilisers, with double input voltage range. The system allows the stabiliser to operate under very bad input voltage coditions up to a ±25% wit hthe same accuracy.When the input voltage situation is not critical, the stabiliser allows to apply a load up to twice the rated powerwith a capacity of regulation up to ±15%.

All models are fitted with a digital voltmeter with input and output reading switch, a pilot lamp and a fused crcuit breaker up to 10kVA

double range electromechanical voltage stabilisers SVD

Power from 1,6kVA to 20kVA
Input voltage 220V
Input acceptable variation from 165V to 270V (gamma estesa) 
from 190 to 245V (potenza massima)
Output voltage 220V
Output voltage accuracy ± 1.5% 
Output stabilised fine voltage regulation ± 5%
Frequency 50/60Hz
Regulation speed 20/1000 sec. / Volt
Load tolerable variation da 0 a 100%
Power factor acceptable variation 0 - 1
Full load efficiency > 98%
Harmonic distortion < 0,5%
Ambient temperature 0° : 45°C
Altitude up to 1000m. above sea level without derating
Applied standards IEC 686
Protections Fused circuit breaker up to 10kVA
RFI protection on control circuit board
Overvoltage protection on control circuit board
Standard accessories Fused circuit breaker (up to 10kVA), digital voltmeter with input/output voltage reading selector, Fine output stabilised voltage regulation screw up to  ±5%, pilot light, in/out terminals on the rear side
power kVA part no. dimensions mm. DWG weight
in.  190/245V in. 165/270V A B C kg.
3.2 1.6 SVD03KD 485 510 177 A 21.0
4.6 2.3 SVD04KD 485 510 177 A 23.0
6.0 3.0 SVD06KD 485 510 226 A 30.0
8.0 4.0 SVD08KD 485 510 226 A 32.0
10.0 5.0 SVD10KD 485 510 226 A 40.0
15.0 7.5 SVD15KD 600 900 300 B 56.0
20.0 10.0 SVD20KD 600 900 300 B 84.0

A

B

Data shown on this page are for reference only and can be changed withouth further notice